OMRON | Mitsubishi
Home >> Products >> MITSUBISHI >> MelsecNet/Mini
MITSUBISHI Temperature Input module (RTD) A64RD3C
Model: A64RD3C.
4-channel.
Wire platinum RTD 3 (Pt100 (JIS C1604-1989、 DIN43760-1980)、 JPt100 (JIS C1604-1981)).
Conversion rate: 40ms / 1 channel.
47-point terminal block
MITSUBISHI Temperature Input module (RTD) A64RD4C
Model: A64RD4C.
4-channel.
Wire platinum resistance thermometer 4 (Pt100 (JIS C1604-1989、 DIN43760-1980)、JPt100 (JIS C1604-1981)).
Conversion rate: 40ms / 1 channel.
47-point terminal block
MITSUBISHI High-speed counter module AD62C
Model: AD62C.
1 channel.
50/10kpps.
Count input signal: DC5/12/24V.
External Input: DC5/12/24V.
Compare output: transistor output (open collector)、DC12/24V.
Point of 0.1A / 1.
0.8A / 1 Common.
47-point terminal block
MITSUBISHI AC100V input module AJ35PJ-8A
Model: AJ35PJ-8A.
Input AC: 8 points.
AC100V.
10mA.
Response time: 25ms.
8 points per common.
26-point terminal block.
Number of occupied stations: 1 station.
Type Remote I / O unit outside the panel (for optical data link)
MITSUBISHI DC input module AJ35PJ-8D
Model: AJ35PJ-8D.
Input DC: 8 points.
DC12/24V.
4/10mA.
Response time: 10ms.
8 points per common.
Positive common type.
26-point terminal block.
Number of occupied stations: 1 station.
Type Remote I / O unit outside the panel (for optical data link)
MITSUBISHI Relay Output Module AJ35PJ-8R
Model: AJ35PJ-8R.
Contact output: 8 points.
DC24V/AC240V.
Point 2A / 1.
8A / 1 Common.
Response time: 12ms.
8 points per common.
26-point terminal block.
Number of occupied stations: 1 station.
Type Remote I / O unit outside the panel (for optical data link)
MITSUBISHI Triac Output module AJ35PJ-8S1
Model: AJ35PJ-8S1.
Triac outputs: 8 points.
AC100 ~ 240V.
Point of 0.6A / 1.
4A / 1 Common.
Response time: 1ms +0.5 cycle 8 points per common.
26-point terminal block.
Number of occupied stations: 1 station.
Type Remote I / O unit outside the panel (for optical data link)
MITSUBISHI Triac Output module AJ35PJ-8S2
Model: AJ35PJ-8S2.
Triac outputs: 8 points.
AC100 ~ 240V.
Point 2A / 1.
5A / 1 Common.
Response time: 1ms +0.5 cycle 8 points per common.
26-point terminal block.
Number of occupied stations: 1 station.
Type Remote I / O unit outside the panel (for optical data link)
MITSUBISHI Transistor Output module AJ35PJ-8T1
Model: AJ35PJ-8T1.
Transistor output: 8 points.
DC12/24V.
Point of 0.1A / 1.
0.8A / 1 Common.
Response time: 2ms.
8 points per common.
8 points per common.
Sink type.
26-point terminal block.
Number of occupied stations: 1 station.
Type Remote I / O unit outside the panel (
MITSUBISHI Transistor Output module AJ35PJ-8T2
Model: AJ35PJ-8T2.
Transistor output: 8 points.
DC12/24V.
Point of 0.5A / 1.
3.2A / 1 Common.
Response time: 2ms.
8 points per common.
8 points per common.
Sink type.
26-point terminal block.
Number of occupied stations: 1 station.
Type Remote I / O unit outside the panel (
MITSUBISHI Transistor Output module AJ35PJ-8T3
Model: AJ35PJ-8T3.
Transistor output: 8 points.
DC12/24V.
Point 2A / 1.
6A / 1 Common.
Response time: 2ms.
8 points per common.
8 points per common.
Sink type.
26-point terminal block.
Number of occupied stations: 1 station.
Type Remote I / O unit outside the panel (for opt
MITSUBISHI Transmitting transducer AJ35PP-CNV
Model: AJ35PP-CNV.
MELSECNET/MINI-S3 data link system.
A2C converters for transmission system.
Plastic Fiber Cable - Plastic Fiber Cable
80 Results Page 1 of 7    1 2 3 4 5 6 7 Next >>